Fire Door Inspection Sheets

The 2012 edition of the life safety code nfpa 101 requires facilities to complete annual fire and smoke door inspection and testing.
Fire door inspection sheets. Does the active door leaf completely close when. Section 18 2 2 2 1 19 2 2 2 1 requires compliance with section 7 2 1 and section 7 2 1 15 2 requires compliance with nfpa 80 standard. Fire door inspection checklist. Fire doors are vital in keeping people safe in buildings they are an essential part of any structured fire safety plan.
We are certified to perform detailed 13 points fire doors inspection. Fact sheet nfpa 80 for health. Our fire smoke door experts will provide a thorough inspection of all the doors in the building to ensure they are safe and complying with the nfpa code and prepare a detailed report on the condition and function of the fire door on your facilities. 45 minutes 90 minutes.
Is the door undercut no more than inch. The assembly is composed of the fire door frame fire exit hardware door closers hinges locks door bolts and other door components that when combined provide varying degrees of fire protection that is contingent on the door fire rating e g. Still a checkmate fire gap gauge take a look at the edges of the door and frame. Open the door about halfway let go and see.
In addition to all of the components of a fire door assembly. Is the clearance from the door edge to the frame no more than 1 8 inch. To help you implement the advice you are given during the week checkmate fire has compiled a downloadable fire door inspection checklist. Fire door safety week 2018 which runs from september 24th to 30th is designed to promote awareness of the importance of choosing the right fire doors and ensuring they are properly installed and maintained.
Fire doors can only be effective though if they are maintained to the highest standards and are fit to perform their intended function in the event of a fire outbreak. For best results use a checkmate fire gap gauge or use a 1 coin to give a feel for scale this is about 3mm thick. View the vision panel and glass from both sides of the door. Are the doors hinges frame hardware and threshold secure aligned and in working order with no visible signs of damage.
To ensure the safety of a building s occupants regular checks must be performed on all fire doors. Is the door free from missing or broken parts. In addition to the annual inspection and testing of fire door assemblies it is the facility manager s responsibility to retain records in either hard copy or digital form for review by the authority having jurisdiction. Open the door and take a look at the hinges.
Fire doors are fire resistant equipment that need to be checked regularly to make sure they still offer protection to other parts of the building. Manual fire alarm boxes ion detectors photo detectors duct detectors heat detectors waterflow switches supervisory switches other specify.