Fire Door Inspection Checklist Template

Fire doors are vital in keeping people safe in buildings they are an essential part of any structured fire safety plan.
Fire door inspection checklist template. Fire door inspection and maintenance. View the vision panel and glass from both sides of the door. This inspection should be run annually at least. For best results use a checkmate fire gap gauge or use a 1 coin to give a feel for scale this is about 3mm thick.
Fire rated door assemblies a visual inspection includes the following. Inspection and testing form nfpa inspection and testing 1 of 4 alarm notification appliances and circuit information quantity êêêêcircuit style bells horns chimes strobes speakers other specify. Open the door and take a look at the hinges. To ensure the safety of a building s occupants regular checks must be performed on all fire doors.
Open the door about halfway let go and see. Throughout the checklist there will be sub checklists for each section to explore a more detailed assessment of the areas. This detailed fire door inspection checklist can be used to survey the overall condition of fire doors. This may result in a requirement for the doors to be.
Fire door safety week 2018 which runs from september 24th to 30th is designed to promote awareness of the importance of choosing the right fire doors and ensuring they are properly installed and maintained. Fire doors should be regularly inspected for damage that may prevent the door from performing in the event of a fire. Fire door inspection checklist. The frequency of each inspection should be determined by assessing among other things the amount of use the door is subjected to the criticality of the area and who it protects.
This may form part of the risk assessment for the building. To help you implement the advice you are given during the week checkmate fire has compiled a downloadable fire door inspection checklist. In this process street fire inspection checklist we cover how to run a fire safety inspection on a residential or commercial building. Fire doors can only be effective though if they are maintained to the highest standards and are fit to perform their intended function in the event of a fire outbreak.
Fire doors are fire resistant equipment that need to be checked regularly to make sure they still offer protection to other parts of the building. Check door leaf and frames for fire door labels. Upon inspection these doors often don t meet nfpa 80 standard requirements. Manual fire alarm boxes ion detectors photo detectors duct detectors heat detectors waterflow switches supervisory switches other specify.
Still a checkmate fire gap gauge take a look at the edges of the door and frame. Labels are present and legible no holes or breaks of door or frame no signs of damage to the door frame hinges and hardware no parts are missing or broken. The more regular the checks the higher the levels of safety provided.