Fire Door Drop Test Requirements

It requires an annual inspection and drop test on all fire doors to demonstrate proper operation full closure and proper reset.
Fire door drop test requirements. Dates for 2008 include 7th may 26th june 25th september and 20th november. Speed of the curtain during the test must fall at least 6 per second and not more than 24 per second. Idea established this program to assist commercial property consumers in identifying qualified technicians for the installation service and drop testing of rolling steel fire doors. This standard regulates the installation and maintenance of assemblies and devices used to protect openings in walls floors and ceilings against the spread of fire and smoke within into or out of buildings.
Mark cummings is section head of fire testing at chiltern international fire. Nfpa 80 2016 inspection testing and maintenance requirements for swinging fire doors online training more info nfpa 80 2016 balancing safety and security with fire doors dampers and door locking online training series. This in turn makes it more difficult to ensure that the required undercuts under nfpa 80 an undercut of 3 4 of an inch is required for all labeled fire doors exist when the door is installed. The standard for fire doors nfpa 80 addresses general requirements and provisions for the care and maintenance of fire doors.
A 1 1 see annex k for general information about fire doors. Drop test per manufacturer s written instructions. In north american building codes it along with fire dampers is often referred. These fire door drop test requirements are pretty simple.
A fire door is a door with a fire resistance rating sometimes referred to as a fire protection rating for closures used as part of a passive fire protection system to reduce the spread of fire and smoke between separate compartments of a structure and to enable safe egress from a building or structure or ship. Chiltern together with bm trada run timber fire doors explained training days which include a full scale fire door test demonstration. 1 1 1 with the exception of fabric fire safety curtain assemblies this standard addresses assemblies that have. Basically they say that your doors must be inspected at least once a year by a professional who knows they are doing.
Installation and service of rolling steel fire doors is a job for professionals with special expertise in this discipline. When you start going up in the tower of a high rise the level of the flooring can really vary he says.