Exterior Doors Florida Building Code

If the door is equal to or less than 50 percent glass it is considered to be an opaque door.
Exterior doors florida building code. Any other exterior door has a threshold height limited to 7 inches. The sections that apply to the replacement of a door or window are building residential existing building and energy. There are exceptions but these doors must not only pass a forced entry test but also a water infiltration. If you are planning to replace a door or window you must first comply with the existing building section.
For other doors in accordance with chapter 17 of the fbc. For accessibility provisions related to doors refer to the florida building code accessibility. Florida building code menu. Doors provided for egress purposes in numbers greater than required by this code shall meet the requirements of this section.
So for all these reasons the international residential code irc and residential edition of the florida building code fbc r302 5 have safety standards for a door that separates the garage from the house interior. Doors serving a means of egress system shall meet the requirements of this section and section 1022 2. Means of egress doors in the irc. There are those who recommend that an outswing door is more secure from breakins and is safer during hurricane season.
Exterior doors in homes and businesses not only provide security but they also serve as a vital means of egress during a fire or other emergency. The door cannot open directly onto a room used for sleeping purposes bedroom and must be one of the following types. It is also code that these doors swing outward. The replacement of garage doors exterior doors skylights operative and.
The u factor requirements discussed above for vertical fenestration also apply to exterior glass doors. Order a florida building code book florida building code 7th edition 2020 fbc 6th edition 2017 fbc code resources and supplements to the fbc find an amendment or declaratory statement find or submit a non binding interpretation find or submit an accessibility waiver what. 2018 irc section r311 3 1 restricts threshold height a required exit door in residences to 1 inches from the top of the the threshold to the floor or landing on each side of the door. No reference shall be made to codes other than the florida building code.
No proprietary notes such as forbidding copies of this drawing are accepted. Force entry resistance test for sliding glass doors per astm f 842 83 grade 10 or aama 1303 5. The requirements to receive. Glass doors by definition in the iecc are considered to be those which are more than 50 percent glass in area.
In south florida it is the norm for all exterior doors to swing outward. Chapter 16 structural loads. The florida building code is divided into eight major sections. The florida building code adopts by reference the florida fire prevention code as adopted by the state fire marshal.