Exit Door Panic Bar Height

Also known as a crash bar push bar or panic device this mechanism unlatches the door without the need of a key twisting pushing levers or any other unlocking maneuvers.
Exit door panic bar height. This is the facility to gain entry into the building with a key from the door with a panic exit device. Measure and place emergency exit door openers at a minimum height of 15 inches and a maximum height of 48 inches above the floor or building level. Door push pull handles are not fitted to the inside of doors with panic bars. The global door controls th1100edtbarf fire rated touch panic the global door controls th1100edtbarf fire rated touch panic bar is 36 in.
Door openers must not require grasping pinching or twisting of the hand or wrist to operate the door. Doors will be fitted with a cylinder on the outside together with a. 1910 36 d 2 exit route doors must be free of any device or alarm that could restrict emergency use of the exit route if the device or alarm fails. Door handles pulls latches locks and other operating devices shall be installed 34 inches 864 mm minimum and 48 inches 1219 mm maximum above the finished floor.
4 no lock padlock hasp bar chain or other device or combination thereof shall be installed or maintained at any time on or in connection with any door on which panic hardware is required if such device prevents the free use of the door for exiting. A device such as a panic bar that locks only from the outside is permitted on exit discharge doors. The exit device is suitable for all doors aluminum hollow metal or wood where there is no projection on the face. Access doors or gates in.
When panic hardware is used on fire doors it must be fire exit hardware that has been tested per ul 10c positive pressure fire tests of door assemblies or another fire test standard and the. Panic hardware is an emergency exit device installed on commercial doors and fire doors which allows fast and easy egress. The number one instinct when equipping a dual door with panic exit bars is to put top and bottom 2 point latch vertical rod panic exit bars on each door. However if there is an overlap this would restrict exiting to a single door.
Recommended to install at 41 from finished floor to enterline of push rail. Long and comes in an aluminum finish. Use openers that can be operated with one hand. Panic hardware also known as an exit device or fire exit hardware when used on fire doors is designed to provide fast and easy egress to allow building occupants to exit safely in an emergency.